Improve system efficiency via real-time data acquisition
Unlike
traditional passive remote I/O, Active Remote I/O provides Active I/O
messaging that can send message over Ethernet, TCP/IP network on I/O
input status changes or meets certain condition, the message is sent to
host computer. Communication between the host computer and Active
Remote I/O device is concise and efficient. In addition, the message
delivery time is 20 times faster than traditional SCADA systems (50 ms
compared to 1 sec).
No programming! Hassle-free Click&Go™ logic control
Click&Go™
logic is the key to make ioLogik E2000 series become an intelligent
remote I/O. Click&Go™ logic lets you decide when to send I/O data,
and what to say to host computers for simple alarm control and
messaging.
As opposed to using C-language or
PLC-ladder, a person who understands basic logic concepts can do the
configuration themselves, and easily finish their projects. Unlike
passive remote I/O architecture, you can integrate Active Remote I/O’s
input signals into one event to be an integrated message, and set up
local output control at the same time. The unique Click&Go™ logic
is a patent pending technology developed by Moxa.
Unique LCD Display Module for on-site configuration
ioLogik
E2000 series Active Remote I/O provides an optional LCD display module
for on-site management and configuration. The unique display module can
display network and I/O settings, e.g. analog input value, digital
input counter value. The IP, netmask address can be set locally without
carrying a PC.
Independent Configuration for Multi-functional AI and AO
points
Each analog input can be independently configured by voltage or current
mode by software. The analog input channels support various signals
ranging from +/-150 mV to +/-10V at 16-bit resolution.
Typical Application
Features
|
Actively transfer I/O data in real-time over Ethernet |
|
|
Easy-to-use Click&Go™ Logic for local output control
and messaging |
|
|
8-channel analog input for mV, voltage, current signal
with wire-off detection (at 4-20mA) |
|
2-channel
analog output for voltage, current actuator control |
|
Connecting
up to 10 hosts |
|
SNMP
to I/O mapping that works with Network Management System |
|
Quick
programming library for VB, VC, BCB |
|
NIST-traceable
calibration |
|
Specifications
LAN |
|
|
|
1.5 KV magnetic isolation |
|
|
|
Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP (MIB for I/O
and Network), HTTP, Active I/O Messaging, IP filtering |
|
|
|
|
Serial |
|
RS-485 (2-wire): Data+, Data-, GND |
|
|
|
15 KV ESD for all signals |
|
|
|
|
|
Serial Communication Parameters |
|
|
|
Power Requirements |
|
24 VDC nominal, 12 to 48 VDC |
|
|
|
|
|
24 VDC nominal, up to 36 VDC |
|
|
|
|
Mechanical Specifications |
|
|
Environmental |
|
-10 to 60°C (14 to 140°F), 5 to
95% RH |
|
|
|
-40 to 85°C (-40 to 185°F), 5 to
95%RH |
|
|
|
|
|
|
|
|
|
|
Analog Input |
|
|
|
|
|
|
+/-150 mV, +/-500 mV, +/-5 V, +/-10 V,
0 to 20 mA, 4 to 20 mA |
|
|
|
16-bit integer (2's complement) |
|
|
|
+/- 0.1%, FSR @ 25°C, +/- 0.3%, FSR @ 0, 60ºC |
|
|
|
|
|
10 samples/sec (voltage), 6 samples/sec (current) |
|
|
|
|
Built-in resistor
for current input |
|
|
|
Can withstand continuous overvoltage (protection
range-10V to 10V) |
|
|
|
|
Analog Output |
|
|
|
|
|
|
|
|
15 VDC for current output |
|
|
|
16-bit integer (2's complement) |
|
|
|
+/- 0.1%, FSR @ 25C, +/- 0.3%, FSR @ 0, 60ºC
(current)
+/- 0.2%, FSR @ 25C, +/- 0.4%, FSR @ 0, 60ºC (voltage) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Agency Approvals |
|
|
FCC Part 15, CISPR (EN55022) Class A |
|
|
|
IEC61000-4-2 (ESD), level 2/3
IEC61000-4-3 (RS), level 2
IEC61000-4-4 (EFT), level 2
IEC61000-4-5 (Surge), level 3
IEC61000-4-6 (CS), level 2
IEC61000-4-8 (PM), level 1
IEC61000-4-11 (Dip) |
|
|
|
|
|
|
|
|
Specification
Power Requirements |
Power Consumption |
198 mA @ 24 VDC |
Power Input |
24 VDC nominal, 12 to 36 VDC |
Serial Communication Parameters |
Flow Control |
None |
Protocol |
Modbus/RTU |
Data Bits |
8 |
Parity |
None |
Stop Bits |
1 |
Baudrate |
1200 to 115200 bps |
Analog Input |
Isolation |
3K VDC or 2K Vrms |
Input Impedance |
900K ohms (min.) |
Built-in Resistor for Current Input |
120 ohms |
Resolution |
16 bits |
Input Range |
±150 mV, ±500 mV, ±5 V, ±10 V, 0 to 20 mA, 4 to 20 mA |
Sampling Rate (all channels) |
• 10 samples/sec for voltage • 6 samples/sec for current |
Accuracy |
±0.1% FSR @ 25°C ±0.3% FSR @ -10 and 60°C |
I/O Mode |
Voltage / Current |
Inputs and Outputs |
Analog Outputs |
2 channels |
Analog Inputs |
8 channels |
LAN |
Protection |
1.5 KV magnetic isolation |
Ethernet |
1 x 10/100 Mbps, RJ45 |
Protocols |
Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP, HTTP, CGI, SNTP |
Analog Output |
Resolution |
12 bits |
Drive Voltage |
15 VDC for current output |
Accuracy |
±0.1% FSR @ 25°C ±0.3% FSR @ -10 and 60°C |
Output Range |
0 to 10 V, 4 to 20 mA |
Load Resistor |
Less than 250 ohms |
Environmental Limits |
Operating Temperature |
-10 to 60°C (14 to 140°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
Physical Characteristics |
Weight |
under 250 g |
Dimensions |
115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in) |
Wiring |
I/O cable max. 14 AWG |
Standards and Certifications |
EMI |
FCC Part 15 Subpart B Class A, EN 55022 Class A |
Safety |
UL 508 |
Shock |
IEC 60068-2-27 |
Vibration |
IEC 60068-2-6 |
EMS |
IEC 61000-4, IEC 61000-6 |
Freefall |
IEC 60068-2-32 |
Serial Communication |
Interface |
RS-485-2w: Data+, Data-, GND |
Serial Line Protection |
15 KV ESD for all signals |
MTBF (mean time between failure) |
Time |
155,941 hrs |
Database |
Telcordia (Bellcore) |
Warranty |
Warranty Period |
5 years |
Details |
See www.moxa.com/warranty |
$68.00
Stock: 2