Interface |
DIP Switches |
• Port break alarm mask • Enable/disable broadcast storm protection |
Fiber Ports |
100BaseFX ports (SC/ST connector) |
LED Indicators |
PWR1, PWR2, FAULT, 10/100M (TP port), 100M (fiber port) |
Alarm Contact |
1 relay output with current carrying capacity of 1 A @ 24 VDC |
RJ45 Ports |
10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connection |
Power Requirements |
Overload Current Protection |
1.6 A |
Reverse Polarity Protection |
Present |
Input Voltage |
12/24/48 VDC (9.6 to 60 VDC), redundant dual inputs |
Input Current |
EDS-316: 0.27 A @ 24 V EDS-316-M/S/MM/SS/MS: 0.44 A @ 24 V |
Connection |
1 removable 6-pin terminal blocks |
Technology |
Standards |
IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3x for Flow Control |
Flow Control |
IEEE 802.3x flow control, back pressure flow control |
Processing Type |
Store and Forward |
Environmental Limits |
Operating Temperature |
Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
MTBF (mean time between failures) |
Time |
257,000 hrs |
Database |
MIL-HDBK-217F, GB 25°C |
Physical Characteristics |
Weight |
1140 g |
Dimensions |
80.1 x 135 x 105 mm (3.15 x 5.31 x 4.13 in) |
Installation |
DIN-Rail mounting, wall mounting (with optional kit) |
Housing |
Metal, IP30 protection |
Switch Properties |
MAC Table Size |
4 K |
Packet Buffer Size |
1.25 Mbit |
Standards and Certifications |
EMI |
FCC Part 15 Subpart B Class A, EN 55022 Class A |
Safety |
UL 508, UL 60950-1, CSA C22.2 No. 60950-1, EN 60950-1 |
Hazardous Location |
UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nC IIC (EDS-316 Series V2.0 pending) |
Note |
Please check Moxa’s website for the most up-to-date certification status. |
Shock |
IEC 60068-2-27 |
Vibration |
IEC 60068-2-6 |
EMS |
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3, EN 61000-4-6 (CS) (EDS-305/308: Level 2; EDS-309/316: Level 3) |
Freefall |
IEC 60068-2-32 |
Marine |
DNV, GL |
Warranty |
Warranty Period |
5 years |
Details |