The TCF-142-RM series of serial-to-fiber converters are slide-in
modules that work with the TRC-190 chassis. The modules convert from
the RS-232, RS-422, or RS-485 signal to a fiber optic signal.
RS-232/422/485 Side | |
RS-232 Signals | TxD, RxD, SGND |
RS-422 Signals | TxD+, TxD-, RxD+, RxD-, SGND |
RS-485-4w Signals | TxD+, TxD-, RxD+, RxD-, SGND |
RS-485-2w Signals | Data+, Data-, SGND |
Baudrate | 50 bps to 921.6 Kbps |
ESD Protection | 15 KV for all signals |
Optical Fiber | |
Fiber Connector | SC or ST |
Cable Requirements | Single-mode:
8.3/125, 8.7/125, 9/125, or 10/125 ?m Multi-mode: 50/125, 62.5/125, or 100/140 ?m |
Transmission Distance | Single-mode: 40 km Multi-mode: 5 km |
Wavelength | Single-mode: 1310
nm Multi-mode: 850 nm |
Tx Output | Single-mode: >
-5 dBm Multi-mode: > -5 dBm |
RX Sensitivity | Single-mode: -25
dBm Multi-mode: -20 dBm |
Point-to-Point Transmission | Half-duplex or full-duplex |
Physical Characteristics | |
Housing | SPCC |
Dimensions | 86.8 x 136.5 x 21 mm (3.42 x 5.37 x 0.83 in) |
Environmental Limits | |
Operating Temperature | 0 to 60°C (32 to 140°F) |
Operating Humidity | 5 to 95% RH |
Storage Temperature | -20 to 75°C (-4 to 158°F) |
Power Requirements | |
Input Voltage | 12 VDC |
Power Consumption | 150 mA @ 12 V |
Regulatory Approvals | |
EMS | EN61000-4-2 (ESD),
Criteria A, Level 4 EN61000-4-3 (RS), Criteria A, Level 2 EN61000-4-4 (EFT), Criteria A, Level 3 EN61000-4-5 (Surge), Criteria A, Level 3 EN61000-4-6 (CS), Criteria A, Level 2 EN61000-4-8 (PFMF), Criteria A, Level 3 |
CE | Class A |
FCC | Part 15 sub part B Class A |
Freefall | IEC 60068-2-32 |
Warranty | |
Warranty Period | 5 years |
Power Requirements | |
Power Consumption | 150 mA @ 12 V |
Input Voltage | 12 VDC |
Optical Fiber Side | |
Wavelength | Single-mode: 1310 nm Multi-mode: 850 nm |
Transmission Distance | Single-mode: 40 km Multi-mode: 5 km |
Rx Sensitivity | Single-mode: -25 dBm Multi-mode: -20 dBm |
Fiber Connector | SC or ST |
Tx Output | Single-mode: > -5 dBm Multi-mode: > -5 dBm |
Cable Requirements | Single-mode: 8.3/125, 8.7/125, 9/125, or 10/125 μm Multi-mode: 50/125, 62.5/125, or 100/140 μm |
Point-to-Point Transmission | Half-duplex or full-duplex |
Ring Transmission | Half-duplex |
Environmental Limits | |
Operating Temperature | 0 to 60°C (32 to 140°F) |
Storage Temperature | -20 to 75°C (-4 to 158°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
MTBF (mean time between failures) | |
Time | 514,926 hrs |
Database | Telcordia (Bellcore), GB |
RS-232/422/485 Side | |
Connector | DB9 |
ESD Protection | 15 KV for all signals |
RS-422 Signals | TxD+, TxD-, RxD+, RxD-, GND |
RS-485-4w Signals | TxD+, TxD-, RxD+, RxD-, GND |
RS-232 Signals | TxD, RxD, GND |
RS-485-2w Signals | Data+, Data-, GND |
Baudrate | 50 bps to 921.6 Kbps |
Physical Characteristics | |
Dimensions | 86.8 x 136.5 x 21 mm (3.42 x 5.37 x 0.83 in) |
Standards and Certifications | |
EMI | FCC Part 15 Subpart B Class A |
EMS | EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 2, EN 61000-4-4 (EFT) Level 2, EN 61000-4-5 (Surge) Level 2, EN 61000-4-6 (CS) Level 2, EN 61000-4-8 (PFMF) Level 3 |
EMC | CE, FCC |
Freefall | IEC 60068-2-32 |
Green Product | RoHS, CRoHS, WEEE |
Warranty | |
Warranty Period | 5 years |
Details | See http://www.moxa.com/support/warranty.htm |
If you need accessory information for this product, please use our Online Contact Us Form to reach us, our industrial sales team is here to help you find the accessories.