RS-485 communication requires precise timing control to enable and disable the line driver, and the Moxa Turbo Serial Engine chip that powers the CP-118U-I and CP-138U-I boards come with on-chip ADDC® (automatic data direction control) to make RS-485 as easy to use as RS-232.
RS-485 multidrop for up to 31 devices within 1.2 kmThe CP-118U-I's 8 RS-232/422/485 ports and the CP-138U-I's 8RS-422/485 ports can achieve data rates up to 921.6 Kbps, and in RS-485 mode, one serial port can connect up to 31 daisy-chained RS-485 devices within a range of 1.2 km. In addition, the 2 KV optical isolation protection on the CP-118U-I and CP-138U-I boards helps prevent equipment damage for long distance RS-485 communication.
Hardware | |
Comm. Controller | MU860 (16C550C compatible) |
Bus | 32-bit Universal PCI |
Connectors for External Antenna | DB78 female |
Serial Interface | |
Serial Standards | CP-118U-I:
RS-232/422/485 CP-138U-I: RS-422/485 |
Number of Ports | 8 |
Number of Boards | 4 per PC (max.) |
Serial Line Protection | ESD Protection: 15 KV on the board |
Isolation | 2 KV |
Performance | |
Baudrate | 50 bps to 921.6 Kbps |
Serial Communication Parameters | |
Data Bits | 5, 6, 7, 8 |
Stop Bits | 1, 1.5, 2 |
Parity | None, Even, Odd, Space, Mark |
Flow Control | RTS/CTS, XON/XOFF |
I/O Address | Assigned by BIOS |
IRQ | Assigned by BIOS |
Serial Signals | |
RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
RS-422 | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
RS-485-4w | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
RS-485-2w | Data+(B), Data-(A), GND |
Driver Support | |
Operating Systems | CP-118U: Windows (2000, XP/2003/Vista x86/x64, 9X/ME/NT), Windows CE 5.0, Windows XP Embedded, DOS, Linux 2.4/2.6, FreeBSD 4/5, QNX 6 (CP-118U-I only: SCO Open Server 5/6, UnixWare 7) |
Physical Characteristics | |
Dimensions | 105 x 133 mm (4.13 x 5.23 in) |
Environmental Limits | |
Operating Temperature | 0 to 55°C (32 to 131°F) |
Operating Humidity | 5 to 95% RH |
Storage Temperature | -20 to 85°C (-4 to 185°F) |
Regulatory Approvals | EN55022, EN55024, EN61000-3-2, EN61000-3-3, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000-4-11, FCC Part 15 Class B |
Power Requirements | |
Power Consumption | CP-118U-I: 860 mA
@ +5V CP-138U-I: 330 mA @ +5V |
Warranty | |
Warranty Period | 5 years |
Power Requirements | |
Power Consumption | CP-118U-I: 860 mA @ +5 V CP-138U-I: 330 mA @ +5V |
Serial Communication Parameters | |
Flow Control | RTS/CTS, XON/XOFF |
Data Bits | 5, 6, 7, 8 |
Parity | None, Even, Odd, Space, Mark |
Stop Bits | 1, 1.5, 2 |
IRQ | Assigned by BIOS |
I/O Address | Assigned by BIOS |
Hardware | |
Connector | DB78 female |
Bus | 32-bit Universal PCI |
Comm. Controller | MU860 (16C550C compatible) |
Performance | |
Baudrate | 50 bps to 921.6 Kbps |
Environmental Limits | |
Operating Temperature | Standard Models: 0 to 55°C (32 to 131°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
MTBF (mean time between failures) | |
Time | 1,147,210 hrs |
Database | Telcordia (Bellcore), GB |
Physical Characteristics | |
Dimensions | 105 x 133 mm (4.13 x 5.23 in) |
Serial Interface | |
Serial Standards | CP-118U-I: RS-232/422/485 CP-138U-I: RS-422/485 |
Number of Ports | 8 |
Max. No. of Boards per PC | 4 |
Serial Line Protection | |
ESD Protection | 15 KV on the board |
Optical Isolation | 2 KV |
Serial Signals | |
RS-485-4w | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
RS-485-2w | Data+(B), Data-(A), GND |
RS-422 | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
Standards and Certifications | |
EMI | EN 55022, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class B |
EMS | EN 55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS) |
EMC | CE, FCC |
Green Product | RoHS, CRoHS, WEEE |
Driver Support | |
Operating Systems | Windows 9X/ME/NT/2000, Windows XP/2003/Vista/2008/7 x86/x64, Windows CE 5.0/6.0, Windows XP Embedded, DOS, Linux 2.4, Linux 2.6 x86/x64, FreeBSD 4/5, QNX 6, SCO Open Server 5/6, UnixWare 7, Solaris 10 x86/x64 |
Note | Please refer to Moxa's website for the latest driver support information. |
Warranty | |
Warranty Period | 5 years |