Technology: | |
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X), 100BaseFX |
Interface: | |
RJ45 Ports | 10/100BaseT(X) |
Fiber Port(s) | 100BaseFX (SC/ST/LC connectors) |
LED Indicators | PTC-101-HV series: PWR1, Fiber Link, 10/100M (TP port) PTC-101-LV series: PWR1, PWR2, Fiber Link, 10/100M (TP port) |
Alarm Contact | One relay output with current carrying capacity of 1 A @ 24 VDC |
Optical Fiber | |
Power Requirements: | |
Overload Current Protection | 1.6 A (protects against two signals shorted together) |
Connection | Removable terminal block |
Reverse Polarity Protection | Present |
DIP Switches | |
Input Voltage | |
Physical Characteristics: | |
Housing | Aluminum, IP30 protection |
Dimensions | 122.5 x 90 x 20 mm (4.82 x 3.54 x 0.79 in) |
Environmental Limits: | |
Operating Temperature | -40 to 85°C (-40 to 185°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Operating Humidity | 5 to 95% RH |
Agency Approvals: | |
EMI | FCC Part 15, CISPR (EN55022) class A |
EMS | EN61000-4-2 Edition 1.2: 2001-04 (Level 4) EN61000-4-3: 1995+A1: 2001 IEC 61000-4-3: 2002+A1: 2002 (Level 3) EN61000-4-4: 2004 (Level 4) EN61000-4-5: 2001-04 (Level 4) EN61000-4-6: 2004-11 (Level 3) EN61000-4-8: 2001-03 (Level 5) EN61000-4-11: 2004-03 (Criteria B) |
Safety | UL 60950-1 |
Rail Traffic | EN50155/EN50121-4 |
Power Automation | IEC 61850-3, IEEE 1613 |
Warranty: | |
Warranty Period | 5 years |
Interface | |
DIP Switches | |
Fiber Ports | 100BaseFX (SC/ST/LC connectors) |
LED Indicators | PWR1, PWR2, Fiber Link, 10/100M (TP port) |
Alarm Contact | One relay output with current carrying capacity of 1 A @ 24 VDC (LV model only) |
RJ45 Ports | 10/100BaseT(X) |
Power Requirements | |
Overload Current Protection | 1.6 A (protects against two signals shorted together) |
Reverse Polarity Protection | Protects against V+/V- reversal |
Input Voltage | |
Connection | Removable terminal block |
Technology | |
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X), 100BaseFX |
Environmental Limits | |
Operating Temperature | -40 to 85°C (-40 to 185°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Conformal Coating | Available upon request |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
MTBF (mean time between failures) | |
Time | 1,211,613 hrs |
Database | Telcordia (Bellcore), GB |
Physical Characteristics | |
Weight | Product only: 690 g Packaged: 875 g |
Dimensions | 152.15 x 123.46 x 66.65 mm (5.99 x 4.86 x 2.62 in) |
Housing | Metal, IP30 protection |
Standards and Certifications | |
EMI | FCC Part 15 Subpart B Class A, EN 55022 Class A |
Safety | UL 60950-1 |
Rail Traffic | EN 50155, EN 50121-4 |
Note | Refer to the "Environmental Type Tests" table below for more detailed information. |
Vibration | IEC-61850-3, IEC-60870-2-2 |
EMS | EN 61000-4-2 (ESD) Level 4, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 4, EN 61000-4-5 (Surge) Level 4, EN 61000-4-6 (CS) Level 3, EN 61000-4-8 (PFMF) Level 5, EN 61000-4-11 |
EMC | CE, FCC |
Power Automation | IEC 61850-3, IEEE 1613 |
Freefall | IEC 60068-2-32 |
Green Product | RoHS, CRoHS, WEEE |
Warranty | |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |